Logo

Buyonsell is one of the leading lubricant and engine oil suppliers in Turkey with its expertise, experience and vast knowledge since the 2000s.

Contact Information

Social Media

spring

Self-cleaning drum filtration system.

Spring is a self-cleaning drum filtration system with a fixed metal filter cloth, suitable for removing magnetic and non-magnetic particles from neat and emulsified oils.

It is available in 9 models with flow rates from 25 to 1000 l/min neat oil and 50 to 2,000 l/min emulsion.

Drum filtration efficiency can be customised according to customer requirements.

Spring series self-cleaning filters are suitable for many types of machine tools such as: machining centres, deep drilling, transfers, grinding machines, lathes, machining with special high-pressure tools and combined machines.

This type of self-cleaning filter is especially suitable in the mechanical engineering and automotive industries, where there are machining operations involving chip removal with tools, abrasion removal, deformation and washing.

Losma guarantees that each purifier is individually tested through rigorous control procedures. A quality and functional test certificate is issued for each unit.

Spring Compact

Losma guarantees that each purifier is individually tested through rigorous control procedures. A quality and functional test certificate is issued for each unit. Spring Compact is a self-cleaning drum filtration system capable of treating from 100 to 5000 l/min of neat oil or emulsion. Drum filtration efficiency can be customised according to customer requirements.

Spring Compact has the special feature that it only processes the amount of coolant required by the machine; the clean liquid collection tank is welded as a single block with the filter. Spring Compact works in real time, eliminating sludge deposits in the tank and thus guaranteeing zero deposits at the bottom of the machine.

Given the characteristics of the filter, the system is designed and sized to the customer’s specific requirements.

Spring series self-cleaning filters are suitable for many types of machine tools such as: machining centres, deep drilling, transfers, grinding machines, lathes, machining with special high-pressure tools and combined machines.

This type of self-cleaning filter is especially suitable in the mechanical engineering and automotive industries, where there are machining operations involving chip removal with tools, abrasion removal, deformation and washing.

  • The Spring and Spring Compact operating principle involves three phases:
  • The filter cloth covering the drum is perfectly clean. The dirty liquid passes through it, depositing the polluting parts, and it finds the drain opening while passing inside it. Here, the liquid falls into the clean collection tank, from where it is then sent back to the machine tools. During this phase, the drum does not rotate and the dredging system is stationary. The pollutant material that settles on the cloth forms the actual filter layer, which can be up to 10-15mm thick.
  • The filter cloth becomes dirty and the liquid level rises. The dirty liquid continues to deposit pollutants on the surface of the drum, which does not rotate and the dredging system is stationary. The degree of filtration improves due to the thickness of the sludge deposited on the cloth.
  • When the cloth clogging cycle is complete and the liquid can no longer pass through, the best possible degree of filtration is achieved. The longer the filter runs in this condition, the better the average filtration will be. When the liquid in the clean tank reaches the minimum level, the Autoclean cycle starts automatically and the drum rotates. At the end of this phase, the cleaning cycle starts again from the beginning.
  • PERMANENT FILTER MATERIALS
    The Spring system uses a metal filter cloth which is cleaned by the Autoclean system. In this way, no consumable materials are used, significantly reducing maintenance and waste disposal costs.
  • AUTOCLEAN SYSTEM
    This is an automatic cleaning system for the wire cloth used for filtering liquids. Inside the filter is a sensor that rotates the drum when the maximum filter cloth clogging level is reached. During the rotation, a counter-current jet system washes the wire mesh, removing the residue while the dredging system scrapes the sludge from the bottom of the tank, transporting it to the outside.
  • DREDGING SYSTEM 
    It is used for the evacuation of filtered and decanted sludge; it can also be in a magnetic version for ferro-magnetic residues
  • DEMAG
    Magnetic rotating disc pre-filtration system for separating magnetic pollutant particles from coolant.
  • MAGNETIC DREDGING PLATE
    To facilitate the evacuation of ferro-magnetic swarf.
  • ELECTRICAL PANELF
    or supplying all utilities, controlling and managing all signals
  • MUD COMPACTOR
    It is used to reduce the volume of sludge for disposal and to reduce the liquid it contains. However, the level of compaction that can be achieved depends on the type of sludge, the type of liquid and many other factors such as cycle times. Volume and moisture reduction is achieved by squeezing with static load. It has a volume reduction efficiency of 40% to 20% and liquid reduction efficiency of 30% to 10%.
  • DELIVERY PUMPS
    For clean liquid delivery from 0.1 bar to 100 bar.
  • SKIM
    Eliminator of superficial oils allowing the quality of coolants to be maintained for a long time and eliminates odours generated in the presence of anaerobic bacterial flora.
  • CONTAINMENT TANK
    To collect the clean liquid to be returned to the machine tool.
  • BOOSTER TANK
    To collect dirty liquid for filter supply.
Models Dimentions (mm)
A B C D E
F1 400 950 630 2’’ 400
F2 500 950 630 2’’ 400
F3 600 950 630 3" 400

 

Master Max emulsion flow rate (l/min) Max neat oil flow rate (l/min) Tank capacity (l) Weight (filter only)
F1 50 25 170 100
F2 100 50 300 120
F3 150 75 450 140

 

Models Dimentions (mm)
A B C D E
F4 600 1600 1220 4’’ G 800
F5 850 1600 1220 4’’ G 800
F6 1100 1600 1220 DN125- PN16 800
F7 1450 1600 1220 DN125- PN16 800
F8 1100 2400 1520 DN125- PN16 1100
F9 1450 2400 1520 DN125- PN16 1100

 

Master Max emulsion flow rate (l/min) Max neat oil flow rate (l/min) Tank capacity (l) Weight (filter only)
F4 300 150 1150 260
F5 600 300 2000 290
F6 900 450 3000 310
F7 1200 600 4000 350
F8 1600 800 5500 650
F9 2000 1000 7000 850

Nominal flow rate data refers to emulsion with a maximum oil concentration of 5% or neat oil with a maximum viscosity of 20cst at 40°C, and with a filter cloth with a nominal filtration degree of 100μ. The different characteristics of the liquid to be treated, the type of pollutant and its concentration can considerably affect the performance of the purifier. Our technical department is at your disposal to identify the most suitable solution for your needs.